These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab’s stability area but also address your large-scale stability testing requirements.
Newtronic Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems.
This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.
Newtronic has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc.
Offers high-speed data transfer, surpassing serial (RS-485) communication, and adheres to a global standard for communication protocol, enabling data operations from any PC over the LAN without requiring a separate PC interface.
All operations through a single 4" Color touch screen display, PLC IP Address setting, Component Working Hours, Standby system change over, Password protection for set values and calibration mode.
Complete Operations driven through PLC, No Data Loss: Data Storage of upto 1000 readings on the PLC itself, At an interval of 30 mins, data upto 20 days is stored on the PLC itself, Facility to send emails directly from the PLC.
Temperature & Deviations, Door Opening, Component Failure, Mains Failure.
Completely ready-to-use systems, Automatic switch-over upon failure of primary systems to achieve conditions, Switch-over also upon detection of HP/LP & Internal fault, Scheduled & manual change-overs, Recording of all change-overs in the software.
IQ, OQ, PQ, Calibration certificates, Operations & maintenance manuals, GA & Electrical drawings, Material test certificates, Training to end-users.
Mobile alert system, Time of alarm transmission, Name of equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).
When an alarm is triggered, an e-mail is sent to the registered PC or mobile address, *connection to a mail server is required to use e-mail alert.
Temperature Overshoot/Undershoot, Delay Timer to safeguard the Compressor, MCB to cut-off over-current supply, Standby Controlling Sensor upon failure of Primary, Emergency Bell switch inside the Chamber.
21 CFR Part 11 Ready, Single software suitable for upto 20 equipments, Automatic daily data back-up, Alarm logs. Alarm acknowledgement with e-signatures, Audit trails, MKT Calculations, Graphical viewing & data trending, Data export in pdf format.
Password based access control, Restricts access to unauthorized persons
Mobile alert system, Time of alarm transmission, Name of equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).
Temperature Range | 2°C to 8°C |
Temperature Accuracy | ± 0.5°C |
Temperature Uniformity | ± 1°C |
Double walled with 60 mm PUF insulated modular panels with easy on-site assembly | SS 304 Interior & Exterior either SS 304 or Pre Coated GI. |
Stainless Steel Trays | Observation window – 300 x 300 mm |
PVC strip curtain for reducing temperature leakages | Heater line along the door to avoid condensation |
Illuminated working area | Flooring of Linoleum carpet |
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room |
Complete Operations driven through IOT-enabled Controller with data logging capacity of upto 1000 readings | Forced air circulation for uniform temperature |
High-quality PT-100 Temperature sensor | High speed Ethernet based communication |
All operations through a single 7″ Color Touch Screen Display | Safety devices: Low temperature cut-off settable thermostat |
Audio/Visual alarms for deviations | Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual |
ICDAS – A Single Software installation for all Newtronic make equipments | Door Access system (Numeric or Biometric) |
8pt. Temperature Scanner | Mobile Alert System |
Stand by Cooling System with auto switch over | Remote alarm system suitable for upto 4 nos. Newtronic make equipments |
Model | Capacity – CuFt. | Capacity – Litres | Internal Size – (HxWxD) mm | External Size – (HxWxD) mm | Trays Qty. | Tray Size – (WxD) mm |
---|---|---|---|---|---|---|
NLWC208SI | 208 | 5,848 | 2000 x 1360 x 2150 | 2120 x 1480 x 2270 | 20 | 900 x 300 |
NLWC250SI | 250 | 7,017 | 2400 x 1360 x 2150 | 2520 x 1480 x 2270 | 28 | 900 x 300 |
NLWC307SI1 | 307 | 8,600 | 2000 x 2000 x 2150 | 2120 x 2120 x 2270 | 20 | 900 x 600 |
NLWC368SI1 | 368 | 10,320 | 2400 x 2000 x 2150 | 2520 x 2120 x 2270 | 28 | 900 x 600 |
NLWC543SI1 | 534 | 15,216 | 2400 x 2000 x 3170 | 2520 x 2120 x 3290 | 42 | 900 x 600 |
NLWC679SI | 679 | 19,020 | 2400 x 2500 x 3170 | 2520 x 2620 x 3290 | 42 | 900 x 800 |
NLWC1092SI1 | 1092 | 30,600 | 2400 x 2500 x 5100 | 2520 x 2620 x 5220 | 70 | 900 x 800 |
NLWC1787SI | 1787 | 50,040 | 3000 x 4000 x 4170 | 3120 x 4120 x 4290 | 126 | 900 x 600 |
NLWC2857SI | 2857 | 80,019 | 3000 x 5100 x 5230 | 3120 x 5220 x 5350 | 162 | 900 x 800 |
Temperature Range | 20°C to 60°C |
Temperature Accuracy | ± 0.5°C |
Temperature Uniformity | ± 1°C |
Humidity Range | 40% RH to 95% RH |
Humidity Accuracy | ± 2% RH |
Humidity Uniformity | ± 3% RH |
Double walled with PUF insulation. | Stainless Steel trays |
SS 304 Interior & Exterior either SS 304 or Mild Steel | Full-length inner glass door & metal door with gasket & lock on the outside |
Internal LED lights | Forced air circulation for uniform temperature |
PU wheels for easy movement | U-shaped SS tubular heaters |
Non condensing steam injection type humidity system with standby heater & auto switch overs | CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser |
Stand by humidity system with booster humidification | Complete Operations driven through PLC with data logging capacity of upto 1000 readings |
High speed Ethernet based communication | All operations through a single 7″ Color Touch Screen |
High quality imported make T/Rh combo sensor with 4-20 mA output | Safety devices: Low & high temperature cut-off settable thermostats |
Audio/Visual alarms for deviations | Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual |
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments | Door Access system (Numeric or Biometric) |
4pt. Temperature & Humidity Scanner | Mobile Alert system |
Stand by Cooling System with auto switch overs (430 litre & above) | Remote alarm system suitable for 4 nos. Newtronic make equipments |
Model | Capacity – CuFt. | Capacity – Litres | Internal Size – (HxWxD) mm | External Size – (HxWxD) mm | Trays Qty. | Tray Size – (WxD) mm | Approx. Weight – Eqip. Kg | Approx. Weight – Ship. Kg |
---|---|---|---|---|---|---|---|---|
NLHC7SI | 7 | 200 | 800 x 500 x 500 | 1315 x 660 x 985 | 3 | 430 x 460 | 150 | 225 |
NLHC16SI | 16 | 430 | 1200 x 600 x 600 | 1715 x 760 x 1155 | 4 | 530 x 560 | 250 | 325 |
NLHC26SI | 26 | 735 | 1500 x 700 x 700 | 2070 x 860 x 1255 | 5 | 630 x 660 | 275 | 350 |
NLHC34SI | 34 | 1000 | 1500 x 800 x 800 | 2070 x 960 x 1355 | 5 | 730 x 760 | 350 | 425 |
NLHC54SI | 54 | 1500 | 1500 x 1600 x 600 | 2070 x 1760 x 1155 | 10 | 695 x 560 | 350 | 450 |
NLHC71SI | 71 | 2000 | 1500 x 1600 x 800 | 2070 x 1760 x 1355 | 10 | 695 x 760 | 375 | 475 |