Walk-In Cold Room

Walk-In Cold Room have now become a de-facto requirement for companies planning multiple ANDA filings & planning to launching various products simultaneously.

These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab’s stability area but also address your large-scale stability testing requirements.

Newtronic Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems.

This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.

Newtronic has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc.

Features

ETHERNET COMMUNICATION

Offers high-speed data transfer, surpassing serial (RS-485) communication, and adheres to a global standard for communication protocol, enabling data operations from any PC over the LAN without requiring a separate PC interface.

Touch Screen Display

All operations through a single 4" Color touch screen display, PLC IP Address setting, Component Working Hours, Standby system change over, Password protection for set values and calibration mode.

IOT-Enabled Control System

Complete Operations driven through PLC, No Data Loss: Data Storage of upto 1000 readings on the PLC itself, At an interval of 30 mins, data upto 20 days is stored on the PLC itself, Facility to send emails directly from the PLC.

Complete Range of Alarms

Temperature & Deviations, Door Opening, Component Failure, Mains Failure.

Standby Cooling System

Completely ready-to-use systems, Automatic switch-over upon failure of primary systems to achieve conditions, Switch-over also upon detection of HP/LP & Internal fault, Scheduled & manual change-overs, Recording of all change-overs in the software.

Documentation & Training

IQ, OQ, PQ, Calibration certificates, Operations & maintenance manuals, GA & Electrical drawings, Material test certificates, Training to end-users.

Alarm Transmission

Mobile alert system, Time of alarm transmission, Name of equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).

E-mail Alert

When an alarm is triggered, an e-mail is sent to the registered PC or mobile address, *connection to a mail server is required to use e-mail alert.

Safety

Temperature Overshoot/Undershoot, Delay Timer to safeguard the Compressor, MCB to cut-off over-current supply, Standby Controlling Sensor upon failure of Primary, Emergency Bell switch inside the Chamber.

ICDAS Software

21 CFR Part 11 Ready, Single software suitable for upto 20 equipments, Automatic daily data back-up, Alarm logs. Alarm acknowledgement with e-signatures, Audit trails, MKT Calculations, Graphical viewing & data trending, Data export in pdf format.

Touch Screen Door Access System

Password based access control, Restricts access to unauthorized persons

Mobile Alert

Mobile alert system, Time of alarm transmission, Name of equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).

Business Sector

Warehouse

Pharmaceuticals

Food & Beverages

Biotechnology

Features
Temperature Range 2°C to 8°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Double walled with 60 mm PUF insulated modular panels with easy on-site assembly SS 304 Interior & Exterior either SS 304 or Pre Coated GI.
Stainless Steel Trays Observation window – 300 x 300 mm
PVC strip curtain for reducing temperature leakages Heater line along the door to avoid condensation
Illuminated working area Flooring of Linoleum carpet
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room
Complete Operations driven through IOT-enabled Controller with data logging capacity of upto 1000 readings Forced air circulation for uniform temperature
High-quality PT-100 Temperature sensor High speed Ethernet based communication
All operations through a single 7″ Color Touch Screen Display Safety devices: Low temperature cut-off settable thermostat
Audio/Visual alarms for deviations Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Single Software installation for all Newtronic make equipments Door Access system (Numeric or Biometric)
8pt. Temperature Scanner Mobile Alert System
Stand by Cooling System with auto switch over Remote alarm system suitable for upto 4 nos. Newtronic make equipments
Model Capacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTrays Qty. Tray Size – (WxD) mm
NLWC208SI 208 5,848 2000 x 1360 x 2150 2120 x 1480 x 2270 20 900 x 300
NLWC250SI 250 7,017 2400 x 1360 x 2150 2520 x 1480 x 2270 28 900 x 300
NLWC307SI1 307 8,600 2000 x 2000 x 2150 2120 x 2120 x 2270 20 900 x 600
NLWC368SI1 368 10,320 2400 x 2000 x 2150 2520 x 2120 x 2270 28 900 x 600
NLWC543SI1 534 15,216 2400 x 2000 x 3170 2520 x 2120 x 3290 42 900 x 600
NLWC679SI 679 19,020 2400 x 2500 x 3170 2520 x 2620 x 3290 42 900 x 800
NLWC1092SI1 1092 30,600 2400 x 2500 x 5100 2520 x 2620 x 5220 70 900 x 800
NLWC1787SI 1787 50,040 3000 x 4000 x 4170 3120 x 4120 x 4290 126 900 x 600
NLWC2857SI 2857 80,019 3000 x 5100 x 5230 3120 x 5220 x 5350 162 900 x 800
Temperature Range 20°C to 60°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Humidity Range 40% RH to 95% RH
Humidity Accuracy ± 2% RH
Humidity Uniformity ± 3% RH
Double walled with PUF insulation. Stainless Steel trays
SS 304 Interior & Exterior either SS 304 or Mild Steel Full-length inner glass door & metal door with gasket & lock on the outside
Internal LED lights Forced air circulation for uniform temperature
PU wheels for easy movement U-shaped SS tubular heaters
Non condensing steam injection type humidity system with standby heater & auto switch overs CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser
Stand by humidity system with booster humidification Complete Operations driven through PLC with data logging capacity of upto 1000 readings
High speed Ethernet based communication All operations through a single 7″ Color Touch Screen
High quality imported make T/Rh combo sensor with 4-20 mA output Safety devices: Low & high temperature cut-off settable thermostats
Audio/Visual alarms for deviations Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments Door Access system (Numeric or Biometric)
4pt. Temperature & Humidity Scanner Mobile Alert system
Stand by Cooling System with auto switch overs (430 litre & above) Remote alarm system suitable for 4 nos. Newtronic make equipments
ModelCapacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTrays Qty.Tray Size – (WxD) mmApprox. Weight – Eqip. KgApprox. Weight – Ship. Kg
NLHC7SI 7 200 800 x 500 x 500 1315 x 660 x 985 3 430 x 460 150 225
NLHC16SI 16 430 1200 x 600 x 600 1715 x 760 x 1155 4 530 x 560 250 325
NLHC26SI 26 735 1500 x 700 x 700 2070 x 860 x 1255 5 630 x 660 275 350
NLHC34SI 34 1000 1500 x 800 x 800 2070 x 960 x 1355 5 730 x 760 350 425
NLHC54SI 54 1500 1500 x 1600 x 600 2070 x 1760 x 1155 10 695 x 560 350 450
NLHC71SI 71 2000 1500 x 1600 x 800 2070 x 1760 x 1355 10 695 x 760 375 475