Laboratory Refrigerator

Protecting the integrity of your work is imperative which is why laboratories rely only on Newtronic for their expertise in high quality refrigeration solutions.

Our full line of refrigerators provide superior temperature uniformity, reliability and an eco-friendly construction for the safe storage of working and reference standards, vaccines, reagents, raw materials and other critical samples. Newtronic chambers have become the defect standard for stability studies of Refrigerated Products.

They also come with specially designed trays for segregating Working Standards & Reference Standards samples for effective storage & quick retrieval.

The chambers are connected through Ethernet to state-of-the-art 21 CFR Part 11 ready software that provide tools for viewing, trending, alarm management, audit trails, MKT & many other such features.

Remember, your lab is not a kitchen! And therefore, domestic fridges can never be a substitute to industrial refrigerators.

Features

ETHERNET COMMUNICATION

Offers high-speed data transfer, surpassing serial (RS-485) communication, and adheres to a global standard for communication protocol, enabling data operations from any PC over the LAN without requiring a separate PC interface.

Standby Cooling System

Completely ready-to-use systems, Automatic switch-over upon failure of primary systems to achieve conditions, Switch-over also upon detection of HP/LP & Internal fault, Scheduled & manual change-overs, Recording of all change-overs in the software.

Complete Range of Alarms

Temperature & Humidity Deviations, Door Opening, Water Supply Failure, Component Failure, Mains Failure.

Documentation & Training

IQ, OQ, PQ, Calibration certificates, Operations & maintenance manuals, GA & Electrical drawings, Material test certificates, Training to end-users.

Touch Screen Door Access System

Temperature & Humidity Deviations, Door Opening, Water Supply Failure, Component Failure, Mains Failure.

Mobile Alert

Mobile Alert system, Time of Alarm transmission, Name of Equipment, Transmitted Message (Equipment Name, Alarm time, Type of Alarm & Limits)

Safety

Temperature Overshoot/Undershoot, Delay Timer to safeguard the Compressor, MCB to cut-off over-current supply, Standby Controlling Sensor upon failure of Primary, Emergency Bell switch inside the Chamber,

ICDAS Software

21 CFR Part 11 Ready, Single software suitable for upto 20 equipments, Automatic daily data back-up, Alarm logs. Alarm acknowledgement with e-signatures, Audit trails, MKT Calculations, Graphical viewing & data trending, Data export in pdf format.

Business Sector

Warehouse

Pharmaceuticals

Food & Beverages

Biotechnology

Features
Temperature Range 2°C to 8°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Double walled with PUF insulation SS 304 Interior & Exterior either SS 304 or Mild Steel
Full-lenth inner glass door with magnetic gasket Forced air circulation for uniform temperature
Stainless Steel trays PU wheels for easy movement
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser Complete Operations driven through IOT-enabled Controller with data logging capacity of upto 1000 readings
High speed Ethernet based communication All operations through a single 7″ Color Touch Screen Display
High-quality PT-100 Temperature sensor Safety devices: Low temperature cut-off settable thermostats
Audio/Visual alarms for deviations Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments Door Access System (Numeric or Biometric)
4pt. Temperature Scanner Mobile Alert system
Stand by Cooling System with auto switch over (430 litre & above) Remote alarm system suitable for 4 nos. Newtronic make equipments
Model Capacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTrays Qty.Tray Size – (WxD) mmApprox. Weight – Eqip. KgApprox. Weight – Ship. Kg
NLCC7SI 7 200 800 x 500 x 500 1315 x 660 x 965 3 430 X 460 150 225
NLCC16SI 16 430 1200 x 600 x 600 1715 x 760 x 1105 4 530 X 560 250 325
NLCC26SI 26 735 1500 x 700 x 700 2070 x 860 x 1205 5 630 X 660 275 350
NLCC34SI 34 1000 1500 x 800 x 800 2070 x 960 x 1305 5 730 X 760 350 425
NLCC54SI 54 1500 1500 x 1600 x 600 2070 x 1760 x 1105 10 695 X 560 350 450
NLCC71SI 71 2000 1500 x 1600 x 800 2070 x 1760 x 1305 10 695 X 760 375 475
Temperature Range 20°C to 60°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Humidity Range 40% RH to 95% RH
Humidity Accuracy ± 2% RH
Humidity Uniformity ± 3% RH
Double walled with PUF insulation. Stainless Steel trays
SS 304 Interior & Exterior either SS 304 or Mild Steel Full-length inner glass door & metal door with gasket & lock on the outside
Internal LED lights Forced air circulation for uniform temperature
PU wheels for easy movement U-shaped SS tubular heaters
Non condensing steam injection type humidity system with standby heater & auto switch overs CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser
Stand by humidity system with booster humidification Complete Operations driven through PLC with data logging capacity of upto 1000 readings
High speed Ethernet based communication All operations through a single 7″ Color Touch Screen
High quality imported make T/Rh combo sensor with 4-20 mA output Safety devices: Low & high temperature cut-off settable thermostats
Audio/Visual alarms for deviations Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments Door Access system (Numeric or Biometric)
4pt. Temperature & Humidity Scanner Mobile Alert system
Stand by Cooling System with auto switch overs (430 litre & above) Remote alarm system suitable for 4 nos. Newtronic make equipments
ModelCapacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTrays Qty.Tray Size – (WxD) mmApprox. Weight – Eqip. KgApprox. Weight – Ship. Kg
NLHC7SI 7 200 800 x 500 x 500 1315 x 660 x 985 3 430 x 460 150 225
NLHC16SI 16 430 1200 x 600 x 600 1715 x 760 x 1155 4 530 x 560 250 325
NLHC26SI 26 735 1500 x 700 x 700 2070 x 860 x 1255 5 630 x 660 275 350
NLHC34SI 34 1000 1500 x 800 x 800 2070 x 960 x 1355 5 730 x 760 350 425
NLHC54SI 54 1500 1500 x 1600 x 600 2070 x 1760 x 1155 10 695 x 560 350 450
NLHC71SI 71 2000 1500 x 1600 x 800 2070 x 1760 x 1355 10 695 x 760 375 475
Enquire Now
For all your industrial chamber needs or to explore collaboration opportunities, don’t hesitate to reach out. We’re here to assist you in any way we can.
Please enable JavaScript in your browser to complete this form.