For drug products intended for storage at sub-zero temperatures, NEWTRONIC Deep Freezers provide a very optimal solution by offering a wide temperature range from -25°C to 0°C.
The switchover to Standby system is automatic & immediate upon detection of a fault in Primary.
If desired, the switchovers can also be scheduled or manual ones.
They also offer automatic defrost by utilizing a heater to defrost the condenser coils, which cycles on and off, preventing any ice build-up. Their robust compressors and CFC-free insulation help ensure temperature uniformity and sample protection.
Offers high-speed data transfer, surpassing serial (RS-485) communication, and adheres to a global standard for communication protocol, enabling data operations from any PC over the LAN without requiring a separate PC interface.
Complete Operations driven through PLC, No Data Loss: Data Storage of upto 1000 readings on the PLC itself, At an interval of 30 mins, data upto 20 days is stored on the PLC itself, Facility to send emails directly from the PLC.
Completely ready-to-use systems, Automatic switch-over upon failure of primary systems to achieve conditions, Switch-over also upon detection of HP/LP & Internal fault, Scheduled & manual change-overs, Recording of all change-overs in the software.
IQ, OQ, PQ, Calibration certificates, Operations & maintenance manuals, GA & Electrical drawings, Material test certificates, Training to end-users.
All operations through a single 4" Color touch screen display, PLC IP Address setting, Component Working Hours, Standby system change over, Password protection for set values and calibration mode.
Temperature & Humidity Deviations, Door Opening, Water Supply Failure, Component Failure, Mains Failure.
Time of Alarm transmission, Name of Equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).
21 CFR Part 11 Ready, Single software suitable for upto 20 equipments, Automatic daily data back-up, Alarm logs. Alarm acknowledgement with e-signatures, Audit trails, MKT Calculations, Graphical viewing & data trending, Data export in pdf format.
Temperature Overshoot/Undershoot, Delay Timer to safeguard the Compressor, MCB to cut-off over-current supply, Standby Controlling Sensor upon failure of Primary, Emergency Bell switch inside the Chamber.
Temperature & Humidity Deviations, Door Opening, Water Supply Failure, Component Failure, Mains Failure.
When an alarm is triggered, an e-mail is sent to the registered PC or mobile address, *connection to a mail server is required to use e-mail alert.
Temperature Range | -25°C to 0°C |
Temperature Accuracy | ± 3°C |
Temperature Uniformity | ± 5°C |
Double walled with PUF insulation | SS304 Interior & Exterior of Mild Steel |
Stainless Steel Trays | PU wheels for easy movement |
Forced air circulation for uniform temperature | Metal Door with gasket & lock on the outside |
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | Complete operation are driven through IOT-enabled Controller with data logging capacity of upto 1000 readings |
High speed Ethernet based communication | All operations through a single 7″ Color Touch Screen Display |
High-quality PT-100 Temperature sensor | Audio/Visual alarms for deviations |
Complete with DQ, IQ, OQ, PQ ,SOP & Maintenance Manual |
ICDAS -A Single Software installation for all Newtronic make equipments | Remote alarm system suitable for upto 4 nos. Newtronic make equipments |
4 pt. Temperature Scanner | Stand by Cooling System with auto switch over (700 litre & above) |
Mobile Alert System | Door Access System (Numeric or Biometric) |
Model | Capacity – CuFt. | Capacity – Litres | Internal Size – (HxWxD) mm | External Size – (HxWxD) mm | Trays Qty. | Tray Size – (WxD) mm | Approx. Weight – Eqip. Kg | Approx. Weight – Ship. Kg |
---|---|---|---|---|---|---|---|---|
NLDF7MI | 7 | 200 | 510 x 560 x 700 | 1500 x 720 x 880 | 2 | 540 x 605 | 175 | 250 |
NLDF11MI | 11 | 300 | 910 x 560 x 590 | 1955 x 720 x 770 | 3 | 540 x 495 | 225 | 300 |
NLDF14MI | 14 | 400 | 910 x 560 x 785 | 1955 x 720 x 965 | 3 | 540 x 690 | 275 | 350 |
NLDF25MI | 25 | 700 | 1200 x 800 x 730 | 2120 x 960 x 1020 | 4 | 780 x 635 | 300 | 375 |
NLDF34MI | 34 | 1050 | 1200 x 1200 x 730 | 2110 x 1360 x 1020 | 8 | 510 x 635 | 325 | 425 |
NLDF54MI | 54 | 1500 | 1200 x 1500 x 830 | 2110 x 1660 x 1120 | 8 | 660 x 735 | 350 | 450 |
Temperature Range | 20°C to 60°C |
Temperature Accuracy | ± 0.5°C |
Temperature Uniformity | ± 1°C |
Humidity Range | 40% RH to 95% RH |
Humidity Accuracy | ± 2% RH |
Humidity Uniformity | ± 3% RH |
Double walled with PUF insulation. | Stainless Steel trays |
SS 304 Interior & Exterior either SS 304 or Mild Steel | Full-length inner glass door & metal door with gasket & lock on the outside |
Internal LED lights | Forced air circulation for uniform temperature |
PU wheels for easy movement | U-shaped SS tubular heaters |
Non condensing steam injection type humidity system with standby heater & auto switch overs | CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser |
Stand by humidity system with booster humidification | Complete Operations driven through PLC with data logging capacity of upto 1000 readings |
High speed Ethernet based communication | All operations through a single 7″ Color Touch Screen |
High quality imported make T/Rh combo sensor with 4-20 mA output | Safety devices: Low & high temperature cut-off settable thermostats |
Audio/Visual alarms for deviations | Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual |
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments | Door Access system (Numeric or Biometric) |
4pt. Temperature & Humidity Scanner | Mobile Alert system |
Stand by Cooling System with auto switch overs (430 litre & above) | Remote alarm system suitable for 4 nos. Newtronic make equipments |
Model | Capacity – CuFt. | Capacity – Litres | Internal Size – (HxWxD) mm | External Size – (HxWxD) mm | Trays Qty. | Tray Size – (WxD) mm | Approx. Weight – Eqip. Kg | Approx. Weight – Ship. Kg |
---|---|---|---|---|---|---|---|---|
NLHC7SI | 7 | 200 | 800 x 500 x 500 | 1315 x 660 x 985 | 3 | 430 x 460 | 150 | 225 |
NLHC16SI | 16 | 430 | 1200 x 600 x 600 | 1715 x 760 x 1155 | 4 | 530 x 560 | 250 | 325 |
NLHC26SI | 26 | 735 | 1500 x 700 x 700 | 2070 x 860 x 1255 | 5 | 630 x 660 | 275 | 350 |
NLHC34SI | 34 | 1000 | 1500 x 800 x 800 | 2070 x 960 x 1355 | 5 | 730 x 760 | 350 | 425 |
NLHC54SI | 54 | 1500 | 1500 x 1600 x 600 | 2070 x 1760 x 1155 | 10 | 695 x 560 | 350 | 450 |
NLHC71SI | 71 | 2000 | 1500 x 1600 x 800 | 2070 x 1760 x 1355 | 10 | 695 x 760 | 375 | 475 |