WALK-IN COOLING (COLD ROOM) CHAMBERS

These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab's stability area but also address your large-scale stability testing requirements.

Walk-In Chambers have now become a de-facto requirement for companies planning multiple ANDA filings & planning to launching various products simultaneously.

NEWTRONIC Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems. This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.

NEWTRONIC has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc

Download send Inquiry

Features

ETHERNET COMMUNICATION :

  • High-speed data transfer
  • Significantly faster than serial(RS-485) communication
  • Global standard for communication protocol
  • No need for a separate PC interface
  • Data Operations from any PC over the LAN

STANDBY COOLING SYSTEM

  • Completely ready-to-use systems
  • Automatic switch-over upon failure of primary systems to achieve conditions
  • Switch-over also upon detection of HP/LP & Internal fault
  • Scheduled & manual change-overs
  • Recording of all change-overs in the software

PLC-BASED CONTROL SYSTEM

  • Complete Operations driven through PLC
  • No Data Loss: Data Storage of upto 1000 readings on the PLC itself
  • At an interval of 30 mins, data upto 20 days is stored on the PLC itself
  • Facility to send emails directly from the PLC

TOUCH SCREEN DISPLAY

  • All operations through a single 4" Color touch screen display
  • PLC IP Address setting
  • Component Working Hours
  • Standby system change over
  • Password protection for set values and calibration mode

E-MAIL ALERT

  • When an alarm is triggered, an e-mail is sent to the registered PC or mobile address
  • *connection to a mail server is required to use e-mail alert.

Complete Range of Alarms

  • Temperature & Deviations
  • Door Opening
  • Component Failure
  • Mains Failure

DOCUMENTATION & TRAINING

  • IQ, OQ, PQ
  • Calibration certificates
  • Operations & maintanance manuals
  • GA & Electrical drawings
  • Material test certificates
  • Training to end-users

SAFETY

  • Temperature Overshoot/Undershoot
  • MCB to cut-off over-current supply
  • Standby Controlling Sensor upon failure of Primary
  • In Walk-in chambers door can be open from inside
  • Emergency Bell switch inside the Chamber

ICDAS SOFTWARE

  • 21 CFR Part 11 Ready
  • Single software suitable for upto 20 equipments
  • Automatic daily data back-up
  • Alarm logs. Alarm acknowledgement with e-signatures
  • Audit trails
  • MKT Calculations
  • Graphical viewing & data trending
  • Data export in pdf format

TOUCH SCREEN DOOR ACCESS SYSTEM

  • Password based access control
  • Restricts access to unauthorized persons

ALARM TRANSMISSION

  • Mobile alert system
  • Time of alarm transmission
  • Name of equipment
  • Transmitted message(Equipment name, alarm time,type of alarm & limits)
Temperature Range 2°C to 8°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Double walled with 80mm PUF insulated modular panels with easy on-site assembly System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room
SS 304 Interior & Exterior either SS 304 or Powder Coated G.I. Complete Operations driven through PLC with data logging capacity of upto 1000 readings & email facility
Stainless Steel Trays High speed Ethernet based communication
Observation window - 300 x 300 mm All operations through a single 4" Color Touch Screen
Illuminated working area High-quality PT100 temperature sensor
Flooring of Linoleum carpet Safety devices: Low temperature cut-off settable thermostats
Forced air circulation for uniform temperature Audio/Visual alarms for deviations
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser Complete with IQ, OQ, PQ & Operations & Maintenance Manual

Power supply: 230/415 volts 50 Hz main supply. Also available with 60 Hz Cycle.
ICDAS - A Single Software installation for all Newtronic make equipments Door Access system (Numeric or Biometric)
8pt. Temperature Scanners Mobile Alert system
Stand by Cooling System with auto switch overs Remote alarm system suitable for 4 nos. Newtronic make equipments
Model Capacity Internal Size External Size Trays Qty. Tray size
CuFt Liter (H*W*D )mm (H*W*D) mm (W*D)mm
NLWC208SI 208 5,848 2000 x 1360 x 2150 2120 x 1480 x 2270 20 900 x 300
NLWC250SI 250 7,017 2400 x 1360 x 2150 2520 x 1480 x 2270 28 900 x 300
NLWC307SI1 307 8,600 2000 x 2000 x 2150 2120 x 2120 x 2270 20 900 x 600
NLWC368SI1 368 10320 2400 x 2000 x 2150 2520 x 2120 x 2270 28 900 x 600
NLWC428SI2
428
12000
2400 x 2000 x 2500
2520 x 2120 x 2620
14 900 x 600
28 540 x 600
NLWC543SI1 543 15216 2400 x 2000 x 3170 2520 x 2120 x 3290 42 900 x 600
NLWC679SI 679 19020 2400 x 2500 x 3170 2520 x 2620 x 3290 42 900 x 800
NLWC1092SI1
1092
30600
2400 x 2500 x 5100
2520 x 2620 x 5220
56 900 x 800
14 900 x 700
NLWC1787SI 1787 50040 3000 x 4000 x 4170 3120 x 4120 x 4290 126 900 x 600
NLWC2857SI 2857 80019 3000 x 5100 x 5230 3120 x 5220 x 5350 162 900 x 800

Send Enquiry