Ecotronic Walk-In Stability Humidity Chamber

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua enim ad minim veniam, quis nostrud exercitation.

The Ecotronic System – based on the principles of Dew Point Control as per the Psychrometric Chart has resulted in a reduction of Power Consumption by 70% and Water Consumption by 90%.

Over the years, our Investment in R&D has resulted in developing technology aimed at Energy Optimisation.

Features

ETHERNET COMMUNICATION

Offers high-speed data transfer, surpassing serial (RS-485) communication, and adheres to a global standard for communication protocol, enabling data operations from any PC over the LAN without requiring a separate PC interface.

Documentation & Training

IQ, OQ, PQ, Calibration certificates, Operations & maintenance manuals, GA & Electrical drawings, Material test certificates, Training to end-users.

Alarm Transmission

Mobile alert system, Time of alarm transmission Name of equipment, Transmitted message(Equipment name, alarm time, type of alarm & limits).

PLC-Based Control System

Complete Operations driven through PLC, No Data Loss: Data Storage of upto 1000 readings on the PLC itself, At an interval of 30 mins, data upto 20 days is stored on the PLC itself, Facility to send emails directly from the PLC.

Complete Range of Alarms

Temperature & Humidity Deviations, Door Opening, Water Supply Failure, Component Failure, Mains Failure.

Touch Screen Display

All operations through a single 4" Color touch screen display, PLC IP Address setting, Component Working Hours, Standby system change over, Password protection for set values and calibration mode.

ICDAS Software

21 CFR Part 11 Ready, Single software suitable for upto 20 equipments, Automatic daily data back-up, Alarm logs. Alarm acknowledgement with e-signatures, Audit trails, MKT Calculations, Graphical viewing & data trending, Data export in pdf format.

Standby Humidity & Cooling System

Completely ready-to-use systems, Automatic switch-over upon failure of primary systems to achieve conditions, Switch-over also upon detection of HP/LP & Internal fault, Scheduled & manual change-overs, Recording of all change-overs in the software.

E-mail Alert

When an alarm is triggered, an e-mail is sent to the registered PC or mobile address, Connection to a mail server is required to use e-mail alert.

Safety

Temperature Overshoot/Undershoot, Humidity Overshoot, Low water-level, Delay Timer to safeguard the Compressor, MCB to cut-off over-current supply, Standby Controlling Sensor upon failure of Primary, In Walk-in chambers door can be open from inside, Emergency Bell switch inside the Chamber

Touch Screen Door Access System

Password based access control, Restricts access to unauthorized persons.

Business Sector

Pharmaceuticals

Cosmetics

Food & Beverages

Blood Bank

Packageing

Features
Temperature Range 20°C to 60°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Humidity Range 40% RH to 95% RH
Humidity Accuracy ± 2% RH
Humidity Uniformity ± 3% RH
Chamber Operations based on Ecotronic system incorporating the principles of Dew point control as per the Psychrometric Chart Humidity is primarily controlled through the principles of Dew point control (for capacities>8KL)
Double walled with 60mm PUF insulated modular panels with easy on-site assembly CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser
SS 304 Interior & Exterior either SS 304 or Pre Coated GI System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room
Stainless Steel Trays Stand by humidity system with booster humidification
Observation window – 300 x 300 mm Complete Operations driven through PLC with data logging capacity of upto 1000 readings
PVC strip curtain for reducing temperature leakages High speed Ethernet based communication
Illuminated working area All operations through a single 7″ Color Touch Screen
Flooring of Linoleum carpet High quality imported make T/Rh combo sensor with 4-20 mA output
Heater line along the door to avoid condensation Safety devices: Low & High temperature cut-off settable thermostats
U-shaped SS tubular heaters Audio/Visual alarms for deviations
Forced air circulation for uniform temperature Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Single Software installation for all Newtronic make equipments Door Access system (Numeric or Biometric)
8pt. Temperature & Humidity Scanner Mobile Alert System
Stand by Cooling System with auto switch over Remote alarm system suitable for upto 4 nos. Newtronic make equipments
ModelCapacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTray Qty. Tray Size – (WxD) mm
NLWH208SI 208 5,848 2000 X 1360 X 2150 2120 X 1480 X 2270 20 900 X 300
NLWH250SI1 250 7,017 2400 X 1360 X 2150 2520 X 1480 X 2270 28 900 X 300
NLWH307SU 307 8,600 2000 X 2000 X 2150 2120 X 2120 X 2270 20 900 X 600
NLWH368SU1 368 10,320 2400 X 2000 X 2150 2520 X 2120 X 2270 28 900 X 600
NLWH543SU 534 15,216 2400 X 2000 X 3170 2520 X 2120 X 3290 42 900 X 600
NLWH679SU 679 19,020 2400 X 2500 X 3170 2520 X 2620 X 3290 42 900 X 800
NLWH1092SU1 1092 30,600 2400 X 2500 X 5100 2520 X 2620 X 5220 70 900 X 800
NLWH1787SU1 1787 50,040 3000 X 4000 X 4170 3120 X 4120 X 4290 126 900 X 600
NLWH2857SU 2857 80,019 3000 X 5100 X 5230 3120 X 5220 X 5350 162 900 X 800
Temperature Range 20°C to 60°C
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1°C
Humidity Range 40% RH to 95% RH
Humidity Accuracy ± 2% RH
Humidity Uniformity ± 3% RH
Double walled with PUF insulation. Stainless Steel trays
SS 304 Interior & Exterior either SS 304 or Mild Steel Full-length inner glass door & metal door with gasket & lock on the outside
Internal LED lights Forced air circulation for uniform temperature
PU wheels for easy movement U-shaped SS tubular heaters
Non condensing steam injection type humidity system with standby heater & auto switch overs CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser
Stand by humidity system with booster humidification Complete Operations driven through PLC with data logging capacity of upto 1000 readings
High speed Ethernet based communication All operations through a single 7″ Color Touch Screen
High quality imported make T/Rh combo sensor with 4-20 mA output Safety devices: Low & high temperature cut-off settable thermostats
Audio/Visual alarms for deviations Complete with DQ, IQ, OQ, PQ & SOP & Maintenance Manual
ICDAS – A Common Software suitable for 20 nos. Newtronic make equipments Door Access system (Numeric or Biometric)
4pt. Temperature & Humidity Scanner Mobile Alert system
Stand by Cooling System with auto switch overs (430 litre & above) Remote alarm system suitable for 4 nos. Newtronic make equipments
ModelCapacity – CuFt.Capacity – LitresInternal Size – (HxWxD) mmExternal Size – (HxWxD) mmTrays Qty.Tray Size – (WxD) mmApprox. Weight – Eqip. KgApprox. Weight – Ship. Kg
NLHC7SI 7 200 800 x 500 x 500 1315 x 660 x 985 3 430 x 460 150 225
NLHC16SI 16 430 1200 x 600 x 600 1715 x 760 x 1155 4 530 x 560 250 325
NLHC26SI 26 735 1500 x 700 x 700 2070 x 860 x 1255 5 630 x 660 275 350
NLHC34SI 34 1000 1500 x 800 x 800 2070 x 960 x 1355 5 730 x 760 350 425
NLHC54SI 54 1500 1500 x 1600 x 600 2070 x 1760 x 1155 10 695 x 560 350 450
NLHC71SI 71 2000 1500 x 1600 x 800 2070 x 1760 x 1355 10 695 x 760 375 475
Enquire Now
For all your industrial chamber needs or to explore collaboration opportunities, don’t hesitate to reach out. We’re here to assist you in any way we can.