Features

Ethernet Communication

  • High-speed data transfer
  • Significantly faster than serial(RS-485) communication
  • Global standard for communication protocol
  • No need for a separate PC interface
  • Data Operations from any PC over the LAN
 

PLC-based Control System

  • Complete Operations driven through PLC
  • No Data Loss: Data Storage of upto 1000 readings on the PLC itself
  • At an interval of 30 mins, data upto 20 days is stored on the PLC itself
  • Facility to send emails directly from the PLC
 

Touch Screen Display

  • All operations through a single 4" Color touch screen display
  • PLC IP Address setting
  • Component Working Hours
  • Standby system change over
  • Password protection for set values and calibration mode
  • User manual, Troubleshooting and Preventive Maintenance procedure
  • Alarms recordings

Touch Screen Door Access System

  • Password-based access control
  • Restricts access to unauthorized persons
 

Sensor (Temperature & Humidity)

  • High-quality German-make with 4-20mA output
  • Low Drift
  • Fast response time
  • Rugged & Reliable

Humidity System

  • Non-condensing steam injection
  • Includes both, humidifer tank & reservoir tank
  • High-Temperature resistant Float Valve & Float Switches

Cooling System

  • Emerson (Kirloskar) make with eco-friendly refrigerant
  • CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser
 

Standby Humidity & Cooling Systems

  • Completely ready-to-use systems
  • Automatic switch-over upon failure of primary systems to achieve conditions
  • Switch-over also upon detection of HP/LP & Internal faults
  • Scheduled & manual change-overs
  • Booster Cooling for faster recovery
  • Recording of all change-overs in the software

Complete Range of Alarms

  • Temperature & Humidity Deviations
  • Door Opening
  • Water Supply Failure
  • Component Failure
  • Mains Failure
 

Alarm Log

  • Separate alarm log with acknowledgement & e-signatures
  • Time of Alarm |Alarm Type & Equipment
  • Acknowledgement Timestamp | Name of Acknowledger with justifications
 

Alarm Transmissions

  • To Software
  • To Remote Location (such as Security Gate)
  • Through detailed SMS Notification
  • Through email from the PLC
  • Locally at equipment (audio-visual indication & on the display)

Mobile Alert

  • Mobile Alert system
  • Time of Alarm transmission
  • Name of Equipment
  • Transmitted Message (Equipment Name, Alarm time, Type of Alarm & Limits)
 

E-mail alert

  • When an alarm is triggered, an e-mail is sent to the registered PC or mobile address
  • *connection to a mail server is required to use e-mail alert.
  •  

Safety

  • Temperature Overshoot/Undershoot
  • Humidity Overshoot
  • Low water-level
  • Delay Timer to safeguard the Compressor
  • MCB to cut-off over-current supply
  • Standby Controlling Sensor upon failure of Primary
  • In Walk-in chambers door can be open from inside
  • Emergency Bell switch inside the Chamber

Multiple Sensors

  • Either 4 or 8 probes can be placed
  • Helps study the distribution of conditions in the different locations of the chamber
  • Works as an auto-validation system
  • Easy detection of drift in the sensors
  • Helps determine the variations in conditions by change in sample-loading pattern
  •  

DocumentS

  • IQ, OQ, PQ
  • Calibration Certificates
  • Operations & Maintenance Manuals
  • GA & Electrical Drawings
  • Material Test Certificates
  • Training to end-users
 

Audit Support

  • Quick Resolution to NCs
  • Justification to Excursions
  • On-site support
  • Remote support via Team Viewer
  • Documentation
 

ICDAS Software

  • 21 CFR Part 11 Ready
  • Single software suitable for upto 20 equipments
  • Automatic daily data backup
  • Password reset & aging
  • Alarm Logs. Alarm acknowledgement with e-signatures
  • Audit Trails
  • MKT Calculations
  • Graphical Viewing & Data Trending
  • Data export in pdf format